Day: ( 5 \  4 \ 2023) Time: (11:44:58)  TesterNumber:1 
************************************************************
[ConfigID] 
ID=98 3C 98 B3 76 71-BICS2 
[SN Set] 
SN_Set=1 
SN_Type=1 
SN_Len=12 
SN_Start=000000000001 
SN_End=999999999999 
SN_Mask=############ 
[Other] 
SATA_SSC_Enable=0 
[StationName] 
01=EraseAll 
02=RDT 
03=RDTResult 
04=MP 
05=ReMP 
06=ICT 
07=UpdateFW 
08=ScanBad 
[General Info] 
SlotNumber=8 
TestStationSel=3 
TestStation=F1 
WorkingNo=00000000 
ModelName=SATA SSD 
SerialNum=000000000001 
MaxCurrent=400 
[Flash Info] 
Flh_Type=TLC_16K 
Flh_MakeCode=Toshiba 
Flh_ID=98 3c 98 b3 76 71 
Flh_Capacity=131072 
Flh_CapacitySel=0 
Flh_Number=4 
Flh_NumberSel=0 
Flash Clock=100 
Flash Interface=3 
[Device Info] 
SATASpeed=3 
ControllerType=SSD-3111SB 
ICFWVersion=SBFQ61L3 
3111SBISP_CodeVersion=Q61L3 
3111SBISP_MPBINCode=.\Bin\SBFQ61L3.BIN 
3111SBISP_RDTBINCode=.\Bin\SBSC61.2.BIN 
SSD Size=2.5" 
[Options] 
DDRSize=32 
Enable_Set_Custom_SMART_Temperature=1 
Set_Custom_SMART_Temperature=42 
Set_LBTOEB=10 
Smart_Table=0 
SLCPoolSizeSel=0 
Disable_DIPM_Support=1 
Put_Thermal_Sensor=0 
Skip_Check_RDDebugPage=1 
PretestType=1 
PMASetting=42035 
Do_Hard_Bit_Retry_Test=1 
[InfoBlock] 
Byte_290=E8 
Byte_291=03 
[EraseAll] 
Do_Erase_First=1 
Type=09 
    
   [Log] 
[ Success ] Modify InfoBlock OK. 
   [ Info ] MP AP: V2.06_x02(China), MAC Address: , ISP FW: SBFQ61L3.BIN, Station:F1T 
[ Success ] Check Device State OK. 
[ Success ] Check IO State OK- Total take 0.024 sec. 
[ Success ] Check ICVer. OK. 
[ Success ] AES VUC Process OK. 
[ Success ] ISP Program PRAM OK. 
[ Success ] eFuse Info 
       UART : Enable 
       JTAG : Enable 
       Trim good die : 01 
   Get Controller ID : 1C_13_08_13_14_1D_20 
       Trim good die : 01 
       Y Coordination : 1c 
       X Coordination : 13 
       Wafer ID : 08 
       Lot ID 4 : 13 
       Lot ID 3 : 14 
       Lot ID 2 : 1d 
       Lot ID 1 : 20 
       CTL Version : 03 
[ Success ] Check eFuse OK. 
[ Success ] Verify param.ini with Device Info OK. 
   Scan_Flash_SDLL: 
   DiePerFlash=1, SectorPerPage=32 
   Ch=0~1, Bank=0~1 
   FlashMode : 3 FlashClock : 5 FlashODT : 0 Flash(NAND)Drive : 0 PadODTEnable : 0 PadODT : 0  
   PADDriveEnable : 0 ALEPads : 0 CLEPads : 0 WEPads : 0 REPads : 0 FRDYPads : 0  
   WPPads : 0 DQSPads : 0 DataPads : 0 CEPads : 0 ScanRound : 0 Scan Interval : 50  
   Scan_LDPC_Error_Bit : 0x03FF  
   BitMask : 0 SlewRateEnable : 0 SlewRate : 0  EnableOverClocking : 0 
   ErrorID=0x04, ErrorInfo=0x0303 
   FailMapCh0=0x00, FailMapCh1=0x00 
        Fail CE: 0,1,8,9,CE0,CE1,CE8,CE9, 
[ Fail ]  Error Message : Issue Vender_InitialPadAndDrive Command Failed !!!  Fail CE: 0,1,8,9,CE0,CE1,CE8,CE9, 
             Error Code : I_x101 
             AP Command : [a1]-[8]-[e]-[13]-[1]-[0]-[0]-[0]-[a0]-[21]-[0]-[0] 
             OS LastError : [ 0 ] 
             ATA Reg:[0][1][0][0][0][50]
[ Error End ] Time: (11:45: 1) 
Fail Mapping : 0000000000000303     Fail CE: 0,1,8,9,